Atg Tank Monitor a ni
Atg Tank Monitor hi advanced automated tank gauging system a ni a, lei hnuaia leh lei chung lama dahna tank te tan a siam a ni. Inventory hmuh theihna, tank enkawl dan, leh hnathawhna lama himna tihchangtlun nan fuel level, tui level, leh product temperature te enfiah chhunzawm zel a ni.
Product chungchang tlangpui
Atg Tank Monitor hi advanced automated tank gauging system a ni a, lei hnuaia leh lei chung lama dahna tank te tan a siam a ni. Inventory hmuh theihna, tank enkawl dan, leh hnathawhna lama himna tihchangtlun nan fuel level, tui level, leh product temperature te enfiah chhunzawm zel a ni.
Technical lam thil chi hrang hrang
|
Technical Metric / Detail lam a ni |
Industry chungchang sawina |
|
|
Range tehna |
500–6000 mm inkar a ni |
Storage tank hmanna pangngai atan a tha |
|
A tehna dik tak |
±0.5 mm a ni |
High-precision level tehna a ni |
|
Accuracy tih leh rawh |
±0.2 mm a ni |
Stable repeat tehna a ni |
|
Oil Level Resolution a ni |
0.01 mm a ni |
Fine level tehna a ni |
|
Tui Level Resolution |
0.01 mm a ni |
Tui tha tak hriat theihna |
|
Temperature tehna hmun hrang hrang |
Point 5 a hmu |
Multi-point temperature enfiahna |
|
Temperature Sensor atanga a chhuah dan |
0.0625℃a ni |
High-resolution temperature tehna a ni |
|
Output / Inbiakpawhna |
RS-485 a ni |
Industrial lama inbiakpawhna hmanrua |
|
Inbiakpawhna hlat ber (maximum Communication Distance) a ni |
1200 m thleng a ni |
Hmun hla tak-a installation atan a tha |
|
Power Supply a awm bawk |
24VDC a ni |
Voltage hniam-voltage DC power supply a ni |
|
Power hman dan tur |
60 mA aia tlem emaw, a tlukpui emaw a ni |
Power hman tlem a ni |
|
Operating Temperature a ni |
-30℃atanga +60℃thleng |
Operating temperature range zau tak a ni |
|
Protection Class a ni |
IP67 a ni |
Leivut leh tui laka invenna |
|
Explosion-Proof Marking tih a ni |
Ex ia IIAT5 Ga. a ni |
Hazardous-area application bik atana hman tlak |
|
A kaihhnawih hmanrua te |
Zener-type Safety Barrier a ni |
A chhungril takah chuan system configuration him tak a ni |
Core Function hrang hrangte
Fuel Inventory enfiahna: 1.1.Operator-te’n fuel inventory an enfiah theih nan leh storage tank level inthlak danglamna an hriatthiam theih nan real-time product level measurement a pe.
Tui Level & Temperature enfiahna:Tank hnuai lama tui level a hmuchhuak a, temperature measurement point panga hmangin product temperature a enfiah a, tank condition management atan information dang a pe bawk.
High-Precision Level tehna:Tank tehna dik tak atan ±0.5 mm tehna dikna, ±0.2 mm repeat dikna, leh 0.01 mm oil leh tui level resolution a pe chhuak a, chu chu tank tehna dik tak atan a ni.
Long-Distance Data Inbiakpawhna:RS-485 interface hmangin measurement data a thawn chhuak a, inbiakpawhna hlat ber chu m 1200 thleng a ni a, monitoring leh management hmanrua inmil tak nena inzawmna a thlawp a ni.
A Hnathawh Dan
Step 1: Tank Sensor dah dan tur
Sensing assembly hi storage tank chhungah vertically-in tank opening ruat hmangin dah a ni a, stored liquid dik taka enfiah turin dah a ni.
↓
Step 2: Liquid Level hriatchhuah dan
Sensing system hian tank chhunga product level inthlak danglamna a hmuchhuak a, a hmun tehna chu liquid-level data dik takah a chantir a ni.
↓
Step 3: Tui Level & Temperature tehna
He system hian tank hnuai lama tui awm zat a hmuchhuak a, temperature tehna hmun panga chuan hmun hrang hrangah product temperature data a khawlkhawm bawk.
↓
Step 4: Signal Processing & Data chhuah dan
Measurement signal lakkhawmte chu monitoring system-in a process a, chu chuan product level, water level, leh temperature information a siam chhuak a, chu chu enfiah leh enkawl belh zel a ni.
↓
Step 5: RS-485 Data hmanga inbiakpawhna
Processed measurement data chu RS-485 interface hmangin connected monitoring emaw control equipment-ah thawn a ni a, hei hian 1200 m thlenga hlaa data rintlak tak a thawn theih phah a ni.
Installation a ni
Site & Installation tehna: 1.1.ATG Tank Monitor hi dik leh him taka dah theih a nih theih nan tank structure, installation opening, a chhehvel boruak, leh cable routing te endik rawh.
Probe & Sensor hman dan tur:Sensing assembly chu storage tank chhungah vertical-in dah la, product leh tui level tehna dik tak neih theih nan sensing section chu a awmna tur dik takah dah rawh.
Power & Communication inzawmna: 1.1.System chu 24VDC power supply mamawh nen connect la, RS-485 communication connection chu monitoring emaw management hmanrua inmil tak nen siam rawh.
Calibration leh Testing te chu a hnuaia mi ang hian a ni.Installation zawhah sensor positioning, power supply, communication status, leh measurement reading te verify la, stable operation leh tank monitoring dik tak a awm theih nan.

Main Interface a ni

Customer Leh Exhibition hrang hrang te

fAQ tih hi a ni
Q: ATG Tank Monitor hian eng nge a teh theih?
A: ATG Tank Monitor hi storage tank chhunga product level, tui level, leh product temperature te enfiahna atana siam a ni. Operator-te fuel inventory track leh tank dinhmun real time-a enfiah theihna turin measurement data dik tak a pe a ni.
Q: ATG Tank Monitor hian a tehna range leh a dikna chu engzat nge ni?
A: ATG Tank Monitor hian a tehna 500–6000 mm a nei a. Measurement accuracy ±0.5 mm leh repeat accuracy ±0.2 mm a pe a, storage tank application atana liquid-level monitoring dik tak a thlawp a ni.
Q: Engtin nge ATG Tank Monitor hian storage tank chhunga tui a hriat theih?
A: He system hi storage tank hnuai lama tui awm zat hriat theihna tura siam a ni a, chutih rualin product level a enfiah bawk. Tui-level resolution hi 0.01 mm a tling thei a, hei hian operator-te chu tui level inthlak danglamna a hriat theih bakah tank dinhmun a enfiah tha zawk a ni.
Q: Engtin nge system hian product temperature a enfiah?
A: ATG Tank Monitor hian tank chhunga hmun hrang hranga product temperature enfiah nan temperature measurement point panga a hmang a. Temperature sensor resolution hi 0.0625℃a ni a, tank monitoring leh inventory management atan temperature information kimchang tak a pe a ni.
Q: ATG Tank Monitor hian eng communication interface nge a hman?
A: ATG Tank Monitor hian RS-485 communication interface hmangin monitoring emaw management hmanrua nena inmil tur data thawn chhuahna atan a hmang a. Communication distance sang ber chu m 1200 thleng a ni thei a, hei hian storage tank leh monitoring equipment te inhlat taka awmna installation atan a tha hle.
Q: Eng power supply leh operating condition nge mamawh?
A: ATG Tank Monitor hian 24VDC power supply hmangin hna a thawk a, product power consumption chu 60 mA aia tam a ni lo. A hnathawhna temperature range tarlan chu -30℃atanga +60℃thleng a ni a, hei hian environment dinhmun hrang hrangah rintlak taka hnathawh theihna a siamsak a ni.
Q: ATG Tank Monitor hi fuel dahna hmun hlauhawm takah a tha em?
A: ATG Tank Monitor hi Ex ia IIAT5 Ga explosion-proof marking hmanga tarlan a ni a, a kaihhnawih hmanrua atan zener-type safety barrier a hmang. IP67 protection a nei bawk. Installation leh system configuration-ah hian local hazardous-area leh himna atana thil tul awmte a zawm tur a ni.
hot tags .: atg tank monitor, China atg tank monitor siamtu, supplier, factory
Inquiry thawn rawh .