
Tank Gauge System hmanga siam a ni
Automatic Tank Gauge System hi fuel leh liquid dahna atana tank monitoring solution a ni a, ATG monitoring console leh magnetostrictive rigid rod probe te a hmang dun a ni. Product level, tui level leh temperature a teh a, tank configuration, tank volume chhiar, alarm connection, RS232/RS485 communication leh remote monitoring te a support bawk.
Product chungchang tlangpui
Automatic Tank Gauge System hi fuel leh liquid dahna atana tank monitoring solution a ni a, ATG monitoring console leh magnetostrictive rigid rod probe te a hmang dun a ni. Product level, tui level leh temperature a teh a, tank configuration, tank volume chhiar, alarm connection, RS232/RS485 communication leh remote monitoring te a support bawk.
ATG System Component hrang hrangte
Centralized ATG Monitoring Console hmanga siam a ni
ATG console hian centralized tank monitoring leh configuration chu color capacitive touchscreen hmangin a pe a ni. Android-based interface hian tank leh probe settings, tank table configuration, measurement display leh remote access te a support a ni.
Magnetostrictive Rigid Rod Probe hmanga siam a ni
Probe hi storage tank chhungah dah a ni a, hei hian product level, tui level leh product temperature te a teh a ni. Magnetostrictive sensing hian liquid-level tehna atan magnetic float position a hmuchhuak thin.
Zener-Type Hriselna Danglamna
Zener-type safety barrier hi listed hazardous-area configuration-a probe nen hman a ni a, probe leh ATG console inkara associated interface a pe a ni.
System Connection a awm bawk
Storage Tank → Magnetostrictive Probe → Zener-Type Safety Barrier → ATG Console → Pawn lam hmanrua / Hmun hla tak atanga enkawl
Probe hian tank data a khawlkhawm a, safety barrier hian a kaihhnawih hazardous-area interface a pe a, ATG console hian tehnate chu a entir a, a process bawk.
Inbiakpawhna & Pawn lam Device Integration
RS232 & RS485 Inbiakpawhna hmanrua te
ATG system hian pawn lam monitoring emaw control equipment nena inzawmna atan RS232 leh RS485 communication interface a pe a ni.
RS485 Inbiakpawhna hlat zawng
ATG system leh connected equipment inkara cable run rei zawk tan chuan RS485 communication distance list sang ber chu 1200 m thleng a ni.
Inbiakpawhna Addressing
Communication address hian digit hnih- format a hmang a, entirnan 01 leh 99 te pawh a hmang a, communication system chhunga device hriat theihna atan.
Pawn lam Device inzawmkhawmna
System configuration a zirin ATG console hian pawn lam audible leh visual alarm device, printer leh overflow valve module te nen a inzawm thei a ni. Heng device te hi duhthlan tur a ni a, order hmain an mamawh zat nen tarlan tur a ni.
Protocol nena inmil theihna
System integration hmain communication protocol hman tur leh receiving monitoring emaw control equipment nena inmilna chu finfiah hmasak tur a ni.
Technical lam thil chi hrang hrang
System & Communication hmanga inbiakpawhna
|
Parameter a ni |
A sawifiahna |
|
Power Supply a awm bawk |
24 VDC a ni |
|
Inbiakpawhna hmanrua (Communication Interfaces) te |
RS232, RS485 a ni |
|
Output Mode a ni |
RS485 a ni |
|
Inbiakpawhna hlat ber (maximum Communication Distance) a ni |
1200 m |
|
Inbiakpawhna Address |
01–99 |
|
Operating Temperature a ni |
-30℃atanga +60℃thleng |
|
Product Power hman zat |
60 mA aia tlem emaw, a tlukpui emaw a ni |
Magnetostrictive Probe hmanga siam a ni
|
Parameter a ni |
A sawifiahna |
|
Range tehna |
500–6000 mm inkar a ni |
|
A tehna dik tak |
±0.5 mm a ni |
|
Accuracy tih leh rawh |
±0.2 mm a ni |
|
Oil Level Resolution a ni |
0.01 mm a ni |
|
Tui Level Resolution |
0.01 mm a ni |
|
Temperature tehna hmun hrang hrang |
5 |
|
Temperature Sensor atanga a chhuah dan |
0.0625℃a ni |
|
Upper Blind Spot a ni |
60 mm a ni |
|
Lower Blind Spot a ni |
50 mm a ni |
|
Probe Puak{0}}Proof Mark |
Ex ia IIA T5 Ga. A rilru a hah lutuk chuan a rilru a buai em em a |
|
A kaihhnawih Safety hmanrua te |
Zener-Type Hriselna Danglamna |
|
Probe humhalhna Class a ni |
IP67 a ni |
Media tha tak tak a ni
Gasoline, paraffin, diesel, light oil, heavy oil, methanol, toluene, ethanol, acetic acid, ethyl ester leh tui dangte tan a tha.
Media compatibility hi order hmain probe materials, seals leh actual operating conditions atanga confirm tur a ni a, a bik takin listed range pawn lama liquids tan chuan.
Configuration & Ordering chungchang hriat tur
Tank Configuration a awm bawk
System configuration atana tank-related information mamawh, tank parameter leh tank table data te pawh pe rawh.
Probe Configuration a awm bawk
Tank tehna mamawh tak tak angin probe tehna range mamawh leh installation ruahmanna chu nemnghet rawh.
Inbiakpawhna Configuration siam dan
Communication interface leh addressing mamawh chu equipment emaw system emaw connect tur angin confirm rawh.
Auxiliary Device siam dan tur ruahmanna siam a ni
External audible leh visual alarm, printer emaw overflow valve module emaw mamawh leh mamawh loh tarlang la, quotation hmain an zat chu confirm hmasa phawt ang che.
Order zat tur
Bulk order atan chuan ATG console, probe leh auxiliary device mamawh zat confirm la, chutiang chuan system configuration kimchang chu dik taka quote theih a ni.

Main Interface a ni

Tank Settings te pawh a awm

Tank Table siam chhuah a ni

Probe Settings te chu a awm

-
Hriatpuina lehkha

FAQ
Q: System hian tank volume chu liquid level tehna atang hian direct-in a chhut em?
A: Ni e. Volume calculation hian configured tank table hmangin liquid level tehna leh tank volume inzawmna a siam a ni.
Q: ATG system-ah hian safety barrier hi a tel em?
A: Listed hazardous-area configuration hian tank probe nena inzawm Zener-type safety barrier a hmang a. Order dawnin configuration mamawh chu tarlan tur a ni.
Q: RS485 communication hi control system eng pawh nen a inmil em?
A: RS485 hian inbiakpawhna interface a sawifiah a. Integration hmain protocol hman tur leh receiving monitoring emaw control equipment nena inmilna chu confirm hmasak phawt tur a ni.
Q: ATG console-ah hian pawn lam alarm emaw printer emaw connect theih a ni em?
A: Ni e. Audible leh visual alarm, printer leh overflow valve module te chu system configuration thlan angin connect theih a ni.
Q: Probe thlan nan eng information nge mamawh?
A: Probe configuration dik tak hriat theih nan tank dimension, measuring range mamawh leh installation arrangement te pek tur a ni.
Q: Chemical liquid enfiah hunah eng nge enfiah tur?
A: Order hmain monitored liquid leh probe materials, seals leh actual operating conditions te inmilna finfiah hmasa phawt ang che.
Q: Production lead time pangngai chu engzat nge ni?
A: Standard production hi ni 15–20 chhungin tihfel a ni tlangpui a, order quantity leh production season a zirin a ni
hot tags .: automatic tank gauge system, China automatic tank gauge system siamtu, supplier, factory
Inquiry thawn rawh .









